Bir Adeziv Sistemin Kanama Durdurucu Ajanlarla Kontamine Edilen Dentin Yüzeyine Bağlanma Dayanımı

Fatma Güller, Mine Şimşek, Fatma Cebe, Esma Yıldız, Cihan Yıldırım
3.019 875


Objectives: The aim of the present study was toevaluate the microtensile bond strength (μTBS) ofself-etch adhesive system to dentin surfacecontaminated with three different hemostatic agentsin the presence of blood and saliva.Materials and Methods: Twelve extractedhuman carious-free permanent molar teeth wereused to obtain flat occlusal dentin surfaces. Thedentin surfaces were grinded with 600 gridsandpaper under water irrigation. Teeth weredivided into four groups (I: Kontrol, II: Ankaferd,III: ViscoStat Clear and IV: Transamine). Thehemostatic agents were aplicated in the presence ofblood and saliva, then were rinsed and dried. Teethwere restored with self-etch adhesive system(Clearfil SE Bond) 2mm thick composite resin(Quadrant Universal LC). Then specimens werestored 37C distilled water during 24 hours. Fivemicrotensile specimens from each tooth measuring1.00 + 0.003 mm were prepared with a slow-speeddiamond saw sectioning machine with a diamondrim blade (n=15). These specimens were attached toopposing arms of the microtensile testing devicewith cyanoacrylate adhesive and fractured undertension at a crosshead speed of 1 mm/min.Statistical analysis was made with one-way analysisof variance (ANOVA) and Tukey tests (α=0.05).Results: μTBS values of groups were (mean ±SD in MPa); I: 28.81±6.84, II: 27.38±4.89, III:24.89±5.80, IV: 24.73±7.14. There was nosignificant differences between μTBS of groups(p>0.05).Conclusions: Contamination of dentin withhemostatic agents didn’t affect the μTBS ofself-etch adeziv sistemlerin bağlanma dayanımınıolumsuzyönde etkilememektedir. Kanamadurdurucu ajanlar self etch adeziv sistemlerinbağlanma dayanımını azaltmaksızın kanamakontrolünde kullanılabilirler.


Dentin-bonding agents, Ankaferd,ViscoStat Clear, Transamine.

Full Text:

PDF (Türkçe)




Xie J, Powers JM, McGuckin RS. In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions. Dental Materials. 1993;9(5):295-9.

Chung CWM, Yiu CKY, King NM, Hiraishi N, Tay FR. Effect of saliva contamination on bond strength of resin luting cements to dentin. Journal of Dentistry. 2009;37(12):923-31.

Kimmes NS, Olson TL, Shaddy RS, Latta MA. Effect of ViscoStat and ViscoStat Plus on composite shear bond strength in the presence and absence of blood. J Adhes Dent. 2006;8(6):363-6.

Yazici AR, Tuncer D, Dayangac B, Ozgunaltay G, Onen A. The effect of saliva contamination on microleakage of an etch-and-rinse and a self-etching adhesive. J Adhes Dent. 2007;9(3):305-9.

Land MF, Couri CC, Johnston WM. Smear layer instability caused by hemostatic agents. J Prosthet Dent. 1996;76(5):477-82.

Kuphasuk W, Harnirattisai C, Senawongse P, Tagami J. Bond Strengths of Two Adhesive Systems to Dentin Contaminated with a Hemostatic Agent. Operative Dentistry. 2007; 32(4):399-405.

Woronko G, Germain H, Meiers J. Effect of dentin primer on the shear bond strength between composite resin and enamel. Oper Dent 1996;21:116-121.

O’Keefe KL, Pinzon LM, Rivera B, Powers JM. Bond strength of composite to astringent-contaminated dentin using self-etching adhesives. Am J Dent. 2005;18:168-72.

Hashimoto M, Ito S, Tay FR, Svizero NR, Sano H, Kaga M & Pashley DH. Fluid movement across the resin-dentin interface during and after bonding. Journal of Dental Research 2004;83(11):843-848.

Unemori M, Matsuya Y, Akashi A, Goto Y & Akamine A. Self-etching adhesives and postoperative sensitivity. American Journal of Dentistry 2004;17(3):191-195.

Harnirattisai C, Kuphasuk W, Senawongse P, J Tagami. Bond Strengths of Resin Cements to Astringent-contaminated Dentin. Operative Dentistry 2009;34-4:415-422.

Ünlü N, Çetin A, Cebe M, Karabekiroğlu S. [Comparison of Micro Tensile Bond Strength of Different Adhesive Systems to Dentin Contaminated with Haemostatic Agents]. Hacettepe Dişhek Fak Derg 2010;34:3-4

Land MF, Rosenstiel SF, Sandrik JL. Disturbance of the dentinal smear layer by acidic hemostatic agents. J Prosth Dent 1994;72:4-7.

Moszner N, Salz U, Zimmermann J. Chemical aspects of self-etching enamel–dentin adhesives: A systematic review. Dent Mater 2005; 21:895–910.

Arslan S, Ertaş H, Zorba YO. Influence of Ankaferd Blood Stopper on shear bond strength of bonding systems. Dent Mater J 2012;31(2):226-31.

This work is licensed under a Creative Commons Attribution-Gayriticari-NoDerivs 3.0 Unported Lisansı